EGL BOMBARDERS AND CHOKES

Bombarder
 
BOMBARDER TRANSFORMERS
15 KVA Bombarder Transformers are suitable for use with all applications, and are generally the recommended choice for this reason. 22 KVA models are best suited for large scale, full-time production shops processing 15-25mm tubing and using primarily 60-120 milliamp electrodes. The EGL model 4600 variable controlled choke is a DC reactance device using a dial Variac. When used in conjunction with the EGL milliamp gauge (item no. 733300) the model 4600 will provide precise control of bombarding levels combined with ease of operation and reliability.
*The use of an EGL Bombarding Milliamp Gauge is recommended.
 
BOMBARDER TRANSFORMER SPECIFICATIONS
Model
Primary
Volt 1
Primary Nominal Amps
Primary
Peak
Amps
Minimum Breaker
Size 2
Minimun Wire
Size 3
15 KVA
240
10-80
100
100A
#2
22 KVA
240
10-80
100
100A
#2
 
Model

Secondary
Volts
Nominal/Peak

Average
Nominal
ma

Peak
ma
Bombarder
Duty
Cycles
15 KVA
26KV/24KV
800
1500
100%
22 KVA
26KV/24KV
800
1750
100%
 
Notes:
1- 208 V services will draw approximately 10% more
2- Minimum 100 Amp service recommended
3- Minimum size included for wire and breaker suitable for most applications. For heavy, continuous production, use next-size-larger wire breaker minimums.
 
CHOKES, BOMBARDERS & VARIACS
Model
Choke Model

Bombarder Only

Variac Only

Choke Complete
(Includes Choke & Variac)
Bombarder
Complete
(Includes Choke, Bombarder, and Variac)
15 KVA 220/60 Hz
718615
716615
718815
718620
716435
15 KVA 220V/50 Hz
718515
716515
718806
718630
718550
22 KVA 220V/60 Hz
718622
716622
718815
718660
718445
22 KVA 220V/50 Hz*
718522
716522
718806
718525
715500
*Special Order
 
Bombarder Contactor (2-pole, 90 amp)includes main contactor assembly, metal enclosure and auxillary contactor
Part No. 718830
 
Contactor Foot Switch (10 amp, 550V, a heavy duty single-pole, double-throw foot switch with guard. A 14 gauge SJ electrical cord with ground required for installation. (Not included)
Part No. 718835
 